12
1615J–PLD–01/06
ATF1502ASV
Notes:
1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. ICC3 refers to the current in the reduced-power mode when macrocell reduced-power is turned on.
Table 9-4.
DC Characteristics
Symbol
Parameter
Condition
Min
Typ
Max
Units
I
IL
Input or I/O Low
Leakage Current
V
IN = VCC
-2
-10
A
I
IH
Input or I/O High
Leakage Current
210
IOZ
Tri-state Output
Off-state Current
VO = VCC or GND
-40
40
A
ICC1
Power Supply Current, Standby
VCC = Max
V
IN = 0, VCC
Std Mode
Com.
40
mA
Ind.
45
mA
I
CC2
Power Supply Current,
Power-down Mode
VCC = Max
VIN = 0, VCC
“PD” Mode
0.75
5.0
mA
ICC3
Reduced-power Mode
Supply Current, Standby
V
CC = Max
VIN = 0, VCC
Std Mode
Com.
25
mA
Ind.
30
mA
VIL
Input Low Voltage
-0.3
0.8
V
IH
Input High Voltage
2.0
V
CCINT + 0.3
V
VOL
Output Low Voltage (TTL)
VIN = VIH or VIL
VCC = MIN, IOL = 8 mA
Com.
0.45
V
Ind.
0.45
Output Low Voltage (CMOS)
V
IN = VIH or VIL
VCC = MIN, IOL = 0.1 mA
Com.
0.2
V
Ind.
0.2
V
OH
Output High Voltage (TTL)
V
IN = VIH or VIL
V
CC = MIN, IOH = 2.0 mA
2.4
V
Output High Voltage (CMOS)
VIN = VIH or VIL
V
CCIO = MIN, IOH = -0.1 mA
V
CCIO - 0.2